WIRING DIAGRAMS:
Connection: 1 phase + 0 + earth, or 2 phases + earth.
Control voltage to relay: 1 phase + 0, or 2 phases.
Connection: 3 phases+ 0 + earth.
Control voltage to relay: 1 phase + 0.
Connection: 3 phases + earth.
Control voltage to relay: 2 phases.
Fuse is only mounted if requested in the receiving country.
(1) * Emergency stop.
(2) * Timer.
(3) # Safety switch for safetyguard.
(5) Safety switch for bowl lift.
* Will only be mounted on request.
# Optional outside the EU.
OBS:
The mixer is to be connected to power via a plug.
The plug must be dimensioned for min. 16 A, 230/
400V~, IP44
When connecting;
1 phase with 0 + earth, use 3 pole plug
2 phases + earth, use 3 pole plug
3 phases + earth, use 4 pole plug
3 phases with 0 + earth, use 5 pole plug